Configuring the Cisco Nexus 2000 Series Fabric Extender

Posted by Peter Kurdziel on March 12, 2013

Configuring a FEX with a Layer 3 Host Interface
Layer 3 Configuration Layer 3 Subinterface Configuration
Layer 3 Host Interface Port Channel Configuration Layer 3 Host Interface Port Channel Subinterface Configuration

The VLAN used in the Layer 3 host interface (HIF) or host interface port channel (HIFPC) subinterface has only local significance to its parent interface. The same VLAN ID can be reused between Layer 3 subinterfaces in the same switch or VDC.

Configuring a Host Interface in a vPC Topology Connected to Two FEXs
Switch 1 Configuration Switch 2 Configuration
Configuring a FEX in Active-Active Mode
Switch 1 Configuration Switch 2 Configuration
    The chassis number (fex-id) for both switches must be the same. Configuring FEX-AA across two VDCs on the same chassis is not supported. FEX-AA does not support Layer 3 interfaces.
Dual-homing of a Server to a FEX with FabricPath
    Enable FabricPath on each switch. Configure the interfaces that you want to designate as FabricPath interfaces. Set the STP priority device to 8192 on all FabricPath Layer 2 gateway devices. (Optional) Set the STP domain ID for each of the separate STP domains that are connected to the FabricPath network. (Optional) Configure a FEX switch ID.

To configure FabricPath interfaces, follow these steps:

See the Cisco Nexus 7000 Series NX-OS Interfaces Configuration Guide for information on configuring FEX.

FEX VPC+ configurations are supported only on F2 modules.

If you are setting up an initial FEX VPC+ configuration on an F Series module, follow these steps:

    In the VPC domain configuration mode, enable partial DF mode with the fabricpath multicast load-balance command. If disabled, enable TRILL style mac-address learning with the mac address-table core-port-learning command. In the VPC domain configuration mode, configure the emulated switch ID with the fabricpath switchid switchid#command. On each of the VPC/VPC+ peer link interfaces in interface configuration mode, enter the switchport mode fabricpath command. On each VPC/VPC+ peer link port channel, enter the VPC peer-link command. Configure the VPC ID with the vpc vpcid command.

If you are changing an existing FEX VPC configuration to a FEX VPC+ configuration on an F Series module, follow these steps:

    In the VPC domain configuration mode, enable partial DF mode with the fabricpath multicast load-balance command. If disabled, enable trill style mac-address learning with the mac address-table core-port-learning command. In the VPC domain configuration mode, configure the emulated switch ID with the fabricpath switchid switchid# command.

Verifying the Configuration

Verifying the Fabric Extender Configuration

Command or Action Purpose
show fex [FEX-number] [detail] Displays information about a specific Fabric Extender or all attached units.
show interface type number fex-intf Displays the Fabric Extender ports that are pinned to a specific switch interface.
show interface fex-fabric Displays the switch interfaces that have detected a Fabric Extender uplink.
show interface ethernet number transceiver [fex-fabric] Displays the SFP+ transceiver and diagnostic optical monitoring (DOM) information for the Fabric Extenderuplinks.
show feature-set Displays the status of the feature sets on the device.
Configuration Examples for the Fabric Extender

This example shows how to display all the attached Fabric Extender units:

This example shows how to display the detailed status of a specific Fabric Extender:

This example shows how to display the Fabric Extender interfaces pinned to a specific switch interface:

This example shows how to display the switch interfaces that are connected to a Fabric Extender uplink:

This example shows how to display the SFP+ transceiver and diagnostic optical monitoring (DOM) information for Fabric Extender uplinks for an SFP+ transceiver that is plugged into the parent switch interface:

This example shows how to display the SFP+ transceiver and DOM information for Fabric Extender uplinks for an SFP+ transceiver that is plugged into the uplink port on the Fabric Extender:

This example shows how to display the status of the feature sets on the device:

This example shows how to display the services used by the Fabric Extender feature set:

Verifying the Chassis Management Information

Command or Action Purpose
show environment fex [temperature | power | fan] Displays the environmental sensor status.
show inventory fex FEX-number Displays inventory information for a Fabric Extender.
show module fex FEX-number Displays module information about a Fabric Extender.
show sprom fex FEX-number | all Displays the contents of the serial PROM (SPROM) on the Fabric Extender.
Configuration Examples for Chassis Management

This example shows how to display the module information about all connected Fabric Extender units:

This example shows how to display the inventory information about a specific Fabric Extender:

This example shows how to display the environment status for a specific Fabric Extender:

This example shows how to display the SPROM for a specific Fabric Extender:

The Network Arcanum™

The Nexus FEX (Fabric Extender) is the 1 gbps fan-out device for the Nexus 5000. The notion of a fabric extender is a new concept to many folks; it is not a stand alone switch. It is managed and configured from the upstream Nexus 5000. To communicate between 2 ports on the Nexus 2148 you must be switched by the Nexus 5000 that feeds it. This means that to go from port 1 to port 2 (on a 2148) you will go to the Nexus 5000 which makes the switching decision and sends it back down to the 2148 to exit port 2.

Connecting the 2148 to a 5000 is surprisingly easy. In this article I will walk you though a very simple configuration. In this topology we have a Nexus 5020 with a Nexus 2148. We’re using Ethernet 1/1 and 1/2 on the 5020 connecting to uplink 1 and 2 on the 2148T.

Once the 2148T is powered up, I ran cables between the 2 port pairs:

5020 Eth1/1 — 2148T uplink 1
5020 Eth1/2 — 2148T uplink 2

Now let’s look at the simple Nexus 5020 configuration needed to use a 2148.

interface Ethernet1/1
switchport mode fex-fabric
fex associate 100

interface Ethernet1/2
switchport mode fex-fabric
fex associate 100

fex 100
pinning max-links 2

By default, a newly created fex group (100 in this instance) will only use 1 link. In this scenario, we have (2) 10 gbps link to be used, so the group was modified to account for both. That was done with the «pinning» command.

That’s all there is to it — the 2148 is now online. At this point, you can start configuring the ports on your 2148. Since the FEX group number created above is 100, you would reference port 1 on the 2148 as «Ethernet 100/1/1».

switch# sh int status

———————————————————————————
Port Name Status Vlan Duplex Speed Type
———————————————————————————
Eth1/1 — up 1 full 10G 1/10g
Eth1/2 — up 1 full 10G 1/10g
Eth1/3 — down 1 full 10G 1/10g
Eth1/4 — down 1 full 10G 1/10g
Eth1/5 — down 1 full 10G 1/10g
Eth1/6 — down 1 full 10G 1/10g
Eth1/7 — down 1 full 10G 1/10g
Eth1/8 — down 1 full 10G 1/10g
Eth1/9 — down 1 full 10G 1/10g
Eth1/10 — down 1 full 10G 1/10g
Eth1/11 — down 1 full 10G 1/10g
Eth1/12 — down 1 full 10G 1/10g
Eth1/13 — down 1 full 10G 1/10g
Eth1/14 — down 1 full 10G 1/10g
Eth1/15 — down 1 full 10G 1/10g
Eth1/16 — down 1 full 10G 1/10g
Eth1/17 — down 1 full 10G 10g
Eth1/18 — down 1 full 10G 10g
Eth1/19 — down 1 full 10G 10g
Eth1/20 — down 1 full 10G 10g
Eth1/21 — down 1 full 10G 10g
Eth1/22 — down 1 full 10G 10g
Eth1/23 — down 1 full 10G 10g
Eth1/24 — down 1 full 10G 10g
Eth1/25 — down 1 full 10G 10g
Eth1/26 — down 1 full 10G 10g
Eth1/27 — down 1 full 10G 10g
Eth1/28 — down 1 full 10G 10g
Eth1/29 — down 1 full 10G 10g
Eth1/30 — down 1 full 10G 10g
Eth1/31 — down 1 full 10G 10g
Eth1/32 — down 1 full 10G 10g
Eth1/33 — down 1 full 10G 10g
Eth1/34 — down 1 full 10G 10g
Eth1/35 — down 1 full 10G 10g
Eth1/36 — down 1 full 10G 10g
Eth1/37 — down 1 full 10G 10g
Eth1/38 — down 1 full 10G 10g
Eth1/39 — down 1 full 10G 10g
Eth1/40 — down 1 full 10G 10g
mgmt0 — down routed auto auto —
Eth100/1/1 — down 1 full 1000 —
Eth100/1/2 — down 1 full 1000 —
Eth100/1/3 — down 1 full 1000 —
Eth100/1/4 — down 1 full 1000 —
Eth100/1/5 — down 1 full 1000 —
Eth100/1/6 — down 1 full 1000 —
Eth100/1/7 — down 1 full 1000 —
Eth100/1/8 — down 1 full 1000 —
Eth100/1/9 — down 1 full 1000 —
Eth100/1/10 — down 1 full 1000 —
Eth100/1/11 — down 1 full 1000 —
Eth100/1/12 — down 1 full 1000 —
Eth100/1/13 — down 1 full 1000 —
Eth100/1/14 — down 1 full 1000 —
Eth100/1/15 — down 1 full 1000 —
Eth100/1/16 — down 1 full 1000 —
Eth100/1/17 — down 1 full 1000 —
Eth100/1/18 — down 1 full 1000 —
Eth100/1/19 — down 1 full 1000 —
Eth100/1/20 — down 1 full 1000 —
Eth100/1/21 — down 1 full 1000 —
Eth100/1/22 — down 1 full 1000 —
Eth100/1/23 — down 1 full 1000 —
Eth100/1/24 — down 1 full 1000 —
Eth100/1/25 — down 1 full 1000 —
Eth100/1/26 — down 1 full 1000 —
Eth100/1/27 — down 1 full 1000 —
Eth100/1/28 — down 1 full 1000 —
Eth100/1/29 — down 1 full 1000 —
Eth100/1/30 — down 1 full 1000 —
Eth100/1/31 — down 1 full 1000 —
Eth100/1/32 — down 1 full 1000 —
Eth100/1/33 — down 1 full 1000 —
Eth100/1/34 — down 1 full 1000 —
Eth100/1/35 — down 1 full 1000 —
Eth100/1/36 — down 1 full 1000 —
Eth100/1/37 — down 1 full 1000 —
Eth100/1/38 — down 1 full 1000 —
Eth100/1/39 — down 1 full 1000 —
Eth100/1/40 — down 1 full 1000 —
Eth100/1/41 — down 1 full 1000 —
Eth100/1/42 — down 1 full 1000 —
Eth100/1/43 — down 1 full 1000 —
Eth100/1/44 — down 1 full 1000 —
Eth100/1/45 — down 1 full 1000 —
Eth100/1/46 — down 1 full 1000 —
Eth100/1/47 — down 1 full 1000 —
Eth100/1/48 — down 1 full 1000 —

switch# show fex 100 detail
FEX: 100 Description: FEX0100 state: Online
FEX version: 4.1(3)N1(1a) [Switch version: 4.1(3)N1(1a)]
FEX Interim version: 4.1(3)N1(1a)
Switch Interim version: 4.1(3)N1(1a)
Extender Model: N2K-C2148T-1GE, Extender Serial: JEX1310EDPD
Part No: 73-12009-05
Card Id: 70, Mac Addr: 00:0d:ec:3b:35:42, Num Macs: 64
Module Sw Gen: 12338 [Switch Sw Gen: 20]
pinning-mode: static Max-links: 2
Fabric port for control traffic: Eth1/1
Fabric interface state:
Eth1/1 — Interface Up. State: Active
Eth1/2 — Interface Up. State: Active
Fex Port State Fabric Port Primary Fabric
Eth100/1/1 Down Eth1/1 Eth1/1
Eth100/1/2 Down Eth1/1 Eth1/1
Eth100/1/3 Down Eth1/1 Eth1/1
Eth100/1/4 Down Eth1/1 Eth1/1
Eth100/1/5 Down Eth1/1 Eth1/1
Eth100/1/6 Down Eth1/1 Eth1/1
Eth100/1/7 Down Eth1/1 Eth1/1
Eth100/1/8 Down Eth1/1 Eth1/1
Eth100/1/9 Down Eth1/1 Eth1/1
Eth100/1/10 Down Eth1/1 Eth1/1
Eth100/1/11 Down Eth1/1 Eth1/1
Eth100/1/12 Down Eth1/1 Eth1/1
Eth100/1/13 Down Eth1/1 Eth1/1
Eth100/1/14 Down Eth1/1 Eth1/1
Eth100/1/15 Down Eth1/1 Eth1/1
Eth100/1/16 Down Eth1/1 Eth1/1
Eth100/1/17 Down Eth1/1 Eth1/1
Eth100/1/18 Down Eth1/1 Eth1/1
Eth100/1/19 Down Eth1/1 Eth1/1
Eth100/1/20 Down Eth1/1 Eth1/1
Eth100/1/21 Down Eth1/1 Eth1/1
Eth100/1/22 Down Eth1/1 Eth1/1
Eth100/1/23 Down Eth1/1 Eth1/1
Eth100/1/24 Down Eth1/1 Eth1/1
Eth100/1/25 Down Eth1/2 Eth1/2
Eth100/1/26 Down Eth1/2 Eth1/2
Eth100/1/27 Down Eth1/2 Eth1/2
Eth100/1/28 Down Eth1/2 Eth1/2
Eth100/1/29 Down Eth1/2 Eth1/2
Eth100/1/30 Down Eth1/2 Eth1/2
Eth100/1/31 Down Eth1/2 Eth1/2
Eth100/1/32 Down Eth1/2 Eth1/2
Eth100/1/33 Down Eth1/2 Eth1/2
Eth100/1/34 Down Eth1/2 Eth1/2
Eth100/1/35 Down Eth1/2 Eth1/2
Eth100/1/36 Down Eth1/2 Eth1/2
Eth100/1/37 Down Eth1/2 Eth1/2
Eth100/1/38 Down Eth1/2 Eth1/2
Eth100/1/39 Down Eth1/2 Eth1/2
Eth100/1/40 Down Eth1/2 Eth1/2
Eth100/1/41 Down Eth1/2 Eth1/2
Eth100/1/42 Down Eth1/2 Eth1/2
Eth100/1/43 Down Eth1/2 Eth1/2
Eth100/1/44 Down Eth1/2 Eth1/2
Eth100/1/45 Down Eth1/2 Eth1/2
Eth100/1/46 Down Eth1/2 Eth1/2
Eth100/1/47 Down Eth1/2 Eth1/2
Eth100/1/48 Down Eth1/2 Eth1/2
Logs:
[11/30/2009 17:24:55.979316] Module register received
[11/30/2009 17:24:55.982666] Registration response sent
[11/30/2009 17:24:56.255137] Module Online Sequence
[11/30/2009 17:24:57.664735] Module Online

With 2 working uplinks, the fan-out ports on the 2148 are statically pinned to an uplink; in this case the first 24 ports use uplink #1 and the last 24 ports use uplink #2. That is easily viewed with the following commands:

switch# show int e1/1 fex-intf
Fabric FEX
Interface Interfaces
—————————————————
Eth1/1 Eth100/1/24 Eth100/1/23 Eth100/1/22 Eth100/1/21
Eth100/1/20 Eth100/1/19 Eth100/1/18 Eth100/1/17
Eth100/1/16 Eth100/1/15 Eth100/1/14 Eth100/1/13
Eth100/1/12 Eth100/1/11 Eth100/1/10 Eth100/1/9
Eth100/1/8 Eth100/1/7 Eth100/1/6 Eth100/1/5
Eth100/1/4 Eth100/1/3 Eth100/1/2 Eth100/1/1

switch# show int e1/2 fex-intf
Fabric FEX
Interface Interfaces
—————————————————
Eth1/2 Eth100/1/48 Eth100/1/47 Eth100/1/46 Eth100/1/45
Eth100/1/44 Eth100/1/43 Eth100/1/42 Eth100/1/41
Eth100/1/40 Eth100/1/39 Eth100/1/38 Eth100/1/37
Eth100/1/36 Eth100/1/35 Eth100/1/34 Eth100/1/33
Eth100/1/32 Eth100/1/31 Eth100/1/30 Eth100/1/29
Eth100/1/28 Eth100/1/27 Eth100/1/26 Eth100/1/25

Having ports statically pinned to a particular uplink port brings up an interesting question. What happens if you lose an uplink port? The user ports on the 2148 go down!

This is the Nexus 5020 port that leads to the 2148:

switch# sh int eth1/1 | inc Ethernet1/1
Ethernet1/1 is up

switch# sh int eth1/1 | inc Ethernet1/1
Ethernet1/1 is down (Link not connected)

We now only have 1 operational FEX port leading to the 2148 which means 1/2 of the ports are dead. All of the ports that were pinned to Eth1/1 (as shown above) are down.

switch# show int eth100/1/1 | inc 100/1/1
Ethernet100/1/1 is down (fabricIfDown)

If you want to avoid this failure scenario, you can assign the physical ports on the Nexus 5000 to a Port Channel and apply the FEX commands to the channel. One slight difference with this approach is that your pinning command would be «pinning max-links 1», the 1 port included is actually the port channel which includes your 2 physical ports. This port channel approach can also be used with a vPC between (2) Nexus 5000s.

Коммутатор (Fabric Extender) Cisco Nexus N2K-C2148T-1GE

Коммутатор (Fabric Extender) Cisco Nexus N2K-C2148T-1GE

Cisco Nexus 2000 Fabric Extender является новым классом продуктов для центров обработки данных, который предоставляет универсальную платформу подключения серверов, включая множество соединений Gigabit Ethernet, 10 Gigabit Ethernet, унифицированные сети, стоечные и блейд серверы. Cisco Nexus 2000 Fabric Extender служит для упрощения архитектуры центров обработки данных и управления сетевой инфраструктурой, отвечая требованиям бизнеса и приложений в вычислительных центрах. Интегрируясь с коммутаторами Cisco Nexus, Cisco Nexus 2000 Fabric Extender предоставляет эффективный метод подключения Gigabit Ethernet соединений, позволяя безболезненно перейти к 10 Gigabit Ethernet, Cisco Data Center Ethernet и технологиям унификации ввода/вывода.

Основные особенности:

  • Функционирует как удалённый модуль ввода/вывода, представляя собой расширение коммутационной матрицы для Nexus 5010 и Nexus 5020;
  • Доступное решение по соотношению цена/порт;
  • Не требует настройки, готово к работе сразу после размещения и подключения;
  • 48 портов 1000Base-T;
  • 4 порта 10GE (SFP+);
  • Переподписка от 1:1 до 4.8:1
  • Компактный 1U форм-фактор;
  • Схема охлаждения «front-to-back», соответствующая концепции горячих и холодных островов в ЦОД;
  • Опциональная возможность установки двух блоков питания с горячей заменой и резервированием;
  • Вентиляторы с горячей заменой

Первым продуктом семейства Cisco Nexus 2000 является Nexus 2148T Fabric Extender. Cisco Nexus 2148T имеет компактный дизайн высотой 1RU и предоставляет 48 портов Gigabit Ethernet для подключения серверов и 4 uplink порта 10 Gigabit Ethernet. Архитектура, применяемая в Cisco Nexus 2148T FEX, идеально подходит для top-of-rack и end-of-row дизайнов. При этом используется охлаждение спереди-назад для соответствия концепции горячих и холодных островов в центрах обработки данных, и все порты для подключения серверов расположены на задней стороне, ближе к серверным интерфейсам. Все заменяемые пользователем компоненты, доступны с передней панели.

Представляет собой расширение коммутационной матрицы для Nexus 5010 и Nexus 5020, доступное по соотношению цена/порт. Размещая Nexus 2148T в любой точке подключения в ЦОД вы получите удалённые интерфейсы, работающие на полной линейной скорости с родительскими устройствами.

Cisco 2148T FEX Port Capabilities Error

When trying to manually configure a host port to run at 100/full on a 2148 FEX I receive an error that states:

ERROR: Configuration does not match the port capability

1 Answer 1

No, it does not. The 2148 FEX has 48 1000Base-T host interfaces. You can confirm this by checking the interface capabilities with the following command (this taken from a 2248 which does support 100Base-TX):

    The Overflow Blog
Related
Hot Network Questions

Subscribe to RSS

To subscribe to this RSS feed, copy and paste this URL into your RSS reader.

Site design / logo © 2023 Stack Exchange Inc; user contributions licensed under CC BY-SA . rev 2023.10.6.43666

By clicking “Accept all cookies”, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *